Marine Cables
Kingfisher Equipment Trading is your trusted energy provider who offers best quality shipboard and offshore cables that range in all sizes. The company continues to prove its excellence in marine electronic solutions by exceeding client’s expectations in meeting quality and on- time delivery standards.
Kingfisher cables product range is in compliance with the national and international standards. Subsequently, our cables have type approval certificates from recognized international marine classification bodies that include TL, BV, LR, GL, DNV, ABS, RMRS, RINA and NK. Kingfisher has a universal presence in the energy and telecommunication arena for which our brand of cables had been installed on vessels locally and internationally.
Write one or two paragraphs describing your product or services.
Cable Properties of our Shipboard cables
Bending Radius | : 6 X Outer Diameter |
Halogen free properties | : IEC 60754- 1 & 2 |
Low smoke emission | : IEC 61034- 1 & 2 |
Flame Retardancy | : IEC 60332-3 CAT.A |
Class | : 2 or 5 |
Power & Lighting Cables
HF m | : Halogen Free |
HFA m EMC | : Halogen Free Armored Cable |
HFA m | : Halogen Free Armored Cable |
HFFR m | : Halogen Free Fire Resistant |
HFFRA m | : Halogen Free Fire Resistant Armored Cable |
Technical Features of Power & Lighting Cables
Rated Voltage | : 0.6/1kV |
Test Voltage | : 3.5kV |
Temperature Range | : -40 C/ +90 C |
Application
Used in ships and sea vehicles for power and lighting applications. Halogen-free, flame retardant and low smoke density type cables.
Telecommunication & Control Cable
HFAT m | : Halogen Free Armored Telecommunication & Control Cable |
HFFRAT m | : Halogen Free Fire Resistant Armored Telecommunication & Control Cable |
HFAT m (C) | : Halogen Free Armored Collectively Screened Telecommunication & Control Cables |
HFAT m (I) | : Halogen Free Armored Individually Screened Telecommunication & Control Cables |
HFAT m (I+C) | : Halogen Free Armored Individually and Collectively Screened Telecommunication & Control Cables |
HFFRAT m (C) | : Halogen Free Fire Resistant Armored Collectively Screened Telecommunication & Control Cable |
HFFRAT m (I) | : Halogen Free Fire Resistant Armored Individually Screened Telecommunication & Control Cables |
HFFRAT m (I+C) | : Halogen Free Fire Resistant Armored Individually & Collectively Screened Telecommunication & Control Cables |
Technical Features of Telecommunication & Control cables
Rated Voltage | : 250 kV |
Test Voltage | : 1.5 kV |
Temperature Range | : -40 C/ +90 C |
Application
Used in ships and sea vehicles for telecommunication and signal applications. Halogen-free, flame retardant and low smoke density type cables.
Table of Standard Design & Tests
Cable Type | IEC 60092-353 | IEC 60092-350 | IEC 60031-21 | IEC 60092-376 |
HF m | x | x | ||
HFA m EMC | x | x | ||
HFA | x | x | ||
HFFR m | x | x | x | |
HFFRA m | x | x | x | |
HFAT m | x | x | ||
HFFRAT m | x | x | x | |
HFAT m (C) | x | x | ||
HFAT m (I) | x | x | ||
HFAT m (I+C) | x | x | ||
HFFRAT m (C) | x | x | x | |
HFFRAT m (I) | x | x | x | |
HFFRAT m (I+C) | x | x | x |
Construction
Conductor
Electrolytic, stranded, annealed bare or tinned copper wire
Insulation
Low smoke, halogen free cross-linked polyolefine (LSX)
Inner Sheath
Halogen-free thermoplastic filler or polyester tape
Outer Sheath
Grey or black colored, halogen-free, low smoke, flame-retardant, polyolefine based thermoplastic compound (TPO)
Technical Features
Halogen free properties | : IEC 60754- 1&2 |
Low smoke emission | : IEC 61034- 1&2 |
Flame Retardancy | : IEC 60332-3 CAT.A |
Standards of Design & Tests | : IEEE 1580-2001 & IEEE 45-2002 & IEC 60331-21 |
Construction
Conductor
Electrolytic, stranded, annealed, bare copper wire- Class 2
Insulation
HEPR
Inner Sheath
Rubber covering or polyester tape
Screen
Copper wire braiding
Outer Sheath
Chloroprene rubber resistant to oil, fuel and flame
Standards of Design & Tests
IEC 60332-3 CAT.C
DIN 89160
DIN 89159
DIN 89158
Construction
Conductor
Electrolytic, stranded, annealed, bare or tinned copper wire- Class 2 or 5
Insulation
PVC
Inner Sheath
PVC
Outer Sheath
PVC compound resistant to oil, fuel and flame
Standards of Design & Tests
IEC 60092-353 & IEC 60092-350
VG 88775
VG 88777
VG 88778
Low Voltage Power and Control Cables 0.6/1kv
RFOU | Halogen Free, Flame Retardant, Low Smoke, Mud Resistant |
BFOU | Halogen Free, Fire Resistant, Flame Retardant, Low Smoke, Mud Resistant |
RU | Halogen Free, Flame Retardant, Low Smoke, optional Mud Resistant |
BU | Halogen Free, Fire Resistant, Flame Retardant, Low Smoke, Optional Mud Resistant |
RFCU | Halogen Free, Flame Retardant, Low Smoke, optional Mud Resistant (Hard Grade EPR) |
BFCU | Halogen Free, Fire Resistant, Flame Retardant, Low Smoke, Optional Mud Resistant (Hard Grade EPR) |
Table of Code letter for Cable Construction
Code Letter | Construction | Construction Details |
R | Insulation | Ethylene propylene rubber (EPR) |
F | Inner Covering | Flame retardant & halogen- free compound |
O | Armour | Tinned annealed Copper wire braid |
U | Outer Sheath | Flame retardant, halogen- free & mud resistant thermoset compound, SHF MUD |
B | Insulation | Mica glass tape + EPR |
C | Armour | Galvanized steel wire braid |
(I) | Individually Screened | Each pair/tripe are screened by copper backed polyester tape in contact with a stranded tinned copper drain wire and wrapped with polyester tape. Printed numbers on insulated conductors identifies Pairs/triples. |
(C) | Collectively Screened | Pairs/triples are laid-up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire. Printed numbers on insulated conductors identifies Pairs/triples. |
Applicable Standards of Our Offshore Cables
IEC 600332-3-22 CAT A: Flame Retardant
IEC 60754- 1 & 2 : Halogen Free Properties
IEC 61034- 1& 2 : Low Smoke Properties
Table of Standard Design & Tests
Cable Type | IEC 60093-353 | IEC 60092-376 | Fire Resistant IEC 60331 |
RFOU | x | ||
BFOU | x | x | |
RU | x | ||
BU | x | x | |
RFCU | x | ||
BFCU | x | x | |
RFOU (I) | x | ||
RFOU (C) | x | ||
BFOU (I) | x | x | |
BFOU (C) | x | x | |
RU (I) | x | ||
RU (C) | x | ||
BU (I) | x | x | |
BU (C) | x | x | |
RFCU (I) | x | ||
RFCU (C) | x | ||
BFCU (I) | x | x | |
BFCU (C) | x | x | |
RU (I+C) | x | ||
BU (I+C) | x | x | |
RFOU VFD | x |
Halogen Free, Flame Retardant, Low Smoke, Mud Resistant
RFOU (I)
RFOU (C)
BFOU (I)
BFOU (C)
Halogen Free, Flame Retardant, Low Smoke, Optional Mud Resistant
RU (I)
RU (C)
RFCU (I) (Hard Grade EPR)
RFCU (C) (Hard Grade EPR)
RU (I+C) (Hard Grade EPR)
Halogen Free, Fire Resistant, Flame Retardant, Low Smoke, Optional Mud Resistant
BU (I)
BU (C)
BFCU (I) (Hard Grade EPR)
BFCU (C) (Hard Grade EPR)
BU (I+C) (Hard Grade EPR)
Table of Code letter for Cable Construction
Code Letter | Construction | Construction Details |
R | Insulation | Ethylene propylene rubber (EPR) |
F | Inner Covering | Flame retardant & halogen- free compound |
O | Armour | Tinned annealed Copper wire braid |
U | Outer Sheath | Flame retardant, halogen- free & mud resistant thermoset compound, SHF MUD |
B | Insulation | Mica glass tape + EPR |
C | Armour | Galvanized steel wire braid |
(I) | Individually Screened | Each pair/tripe are screened by copper backed polyester tape in contact with a stranded tinned copper drain wire and wrapped with polyester tape. Printed numbers on insulated conductors identifies Pairs/triples. |
(C) | Collectively Screened | Pairs/triples are laid-up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire. Printed numbers on insulated conductors identifies Pairs/triples. |
Table of Standard Design & Tests
Cable Type | IEC 60093-353 | IEC 60092-376 | Fire Resistant IEC 60331 |
RFOU | x | ||
BFOU | x | x | |
RU | x | ||
BU | x | x | |
RFCU | x | ||
BFCU | x | x | |
RFOU (I) | x | ||
RFOU (C) | x | ||
BFOU (I) | x | x | |
BFOU (C) | x | x | |
RU (I) | x | ||
RU (C) | x | ||
BU (I) | x | x | |
BU (C) | x | x | |
RFCU (I) | x | ||
RFCU (C) | x | ||
BFCU (I) | x | x | |
BFCU (C) | x | x | |
RU (I+C) | x | ||
BU (I+C) | x | x | |
RFOU VFD | x |
Variable Frequency Drive Cable
RFOU VFD 0.6/1 kV: Halogen Free, Flame Retardant, Low Smoke, VFD Type, Optional Mud Resistant (Hard EPR)
Application
For use in variable frequency AC motor drive (VFD) applications.
Applicable standards
IEC 600332-3-22 CAT A : Flame Retardant
IEC 60754- 1 & 2 : Halogen Free Properties
IEC 61034- 1& 2 : Low Smoke Properties
Table of Code letter for Cable Construction
Code Letter | Construction | Construction Details |
R | Insulation | Ethylene propylene rubber (EPR) |
F | Inner Covering | Flame retardant & halogen- free compound |
O | Armour | Tinned annealed Copper wire braid |
U | Outer Sheath | Flame retardant, halogen- free & mud resistant thermoset compound, SHF MUD |
B | Insulation | Mica glass tape + EPR |
C | Armour | Galvanized steel wire braid |
(I) | Individually Screened | Each pair/tripe are screened by copper backed polyester tape in contact with a stranded tinned copper drain wire and wrapped with polyester tape. Printed numbers on insulated conductors identifies Pairs/triples. |
(C) | Collectively Screened | Pairs/triples are laid-up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire. Printed numbers on insulated conductors identifies Pairs/triples. |